Article - CS297988

Windchill PDMLink: WTPart structure build failed because the related CAD Documents are unverified or not regenerated in the CAD tool

Modified: 14-Aug-2024   


Applies To

  • Pro/INTRALINK 8.x + 11.0 to 12.1
  • Creo Parametric 1.0 to 10.0
  • Windchill PDMLink 11.0 to 13.0
  • Windchill ProjectLink 11.0 to 12.1
  • Windchill PDM Essentials 11.0 to 12.0

Description

  • WTPart structure build failed because the related CAD Documents are unverified or not regenerated in the CAD tool 
  • Although the CAD assembly data checked-in successfully, the WTPart structure is not build and users are unable to use the Build Multi-Level Part Structure to trigger the WTPart structure build
    • EPM Build is set to Windchill PDMLink default on check-in
    • The EPM-WTPart structures are CAD-driven
  • Built WTPart structure fails when using the Build Multi-Level Part Structure operation 
  • Unable to create BOM structure of WTPart after CAD assembly is checked in
  • WTPart structure not building due to error message related to CAD documents that are in the EPM structure
  • Attribute values are not passed from CAD structure to the related WTPart structure
  • Unable to Build Multi-Level Part Structure when assembly which contains circular reference
  • Error message when using Build Multi-Level Part Structure operation :
Error Message
Build Failed: The following Parts were not built, because the related CAD Documents are unverified or not regenerated in the CAD tool "<names of different WTPart objects are listed>"

User-added image
  • BOM (WTPart structure) build failed when some parts or sub-assembly files are failed to regenerate in Creo Parametric.