Article - CS312299

“Open in Creo View” action fails with message "ATTENTION: Error occurred communicating with Windchill. Contact your Windchill administrator for help." in Windchill PDMLink

Modified: 17-Nov-2025   


Applies To

  • Windchill PDMLink 11.0 to 13.0
  • Creo View 3.0 to 12.1
  • Creo Illustrate 7.0 to 11.1
  • Windchill Visualization Services (WVS)

Description

  • Creo View client fails to opens viewable content from SSL configured Windchill PDMLink
  • Getting error message when trying to open CAD objects in Creo View from Windchill details page
  • Error with Windchill request
  • ATTENTION: Error occurred communicating with Windchill. Contact your Windchill administrator for help
image.png
  • Setting the environment variable PVIEW_SEARCH_ALL_CERTIFICATES=1 as described in CS242260 does not solve the problem 
  • When Creo View endusers click on a visualization image from a Windchill WTPart detail page in Windchill Projectlink, an error message is reported
  • Trying to open an illustration file from Windchill PDMLink throws the following error:
  • The selected file cannot be opened from this location
  • Getting a Communication Error when trying to connect Illustrate with Windchill PDMLink:
  • Could not connect to server
           
  • Creo Illustrate & Creo View debug trace logs as per CS62972 report the following :
Info    <date & time> 12724 12816 internet DownloadTask HttpSendRequest failed, error: 12057
Warning <date & time> 12724 12816 internet DownloadTask Unhandled certificate error: 12057
Error   <date & time> 12724 12816 pvsa CvAgent Failed to retrieve Nonce
Error   <date & time> 12724 12780 pvsa CvAgent FAILED_TO_AQUIRE_NONCE_MESSAGE
  • Error occurs when attempting to open representation in Creo View from Windchill PDMLink
  • Sometimes may have error message in Creo View log: 
    Info    10:57:40.162  24 June 2021 20380 20296 dom ExchangeLogic AdvertiseActorName(1, GUI).
    Info    10:57:40.166  24 June 2021 20380 17028 pvsa CvAgent URI_MESSAGE
    Info    10:57:40.166  24 June 2021 20380 17028 pvsa CvAgent baseUrl: http://xxx.com/Windchill
    Info    10:57:40.167  24 June 2021 20380 17028 pvsa CvAgent GET_NONCE_MESSAGE
    Info    10:57:40.167  24 June 2021 20380 17028 pvsa CvAgent GetWindchillNonce
    Error   10:57:40.167  24 June 2021 20380 17028 du FileSystem  Couldn't create temporary file "C:\Users\xxx\AppData\Local\Temp\oidxxxxx.json" - No such file or directory.
    Error   10:57:40.168  24 June 2021 20380 17028 du FileSystem  Couldn't create temporary file  "C:\Users\xxx\AppData\Local\Temp\oidxxxx.json" - No such file or directory.
    ......
    Error   10:57:40.177  24 June 2021 20380 17028 du FileSystem Failed to create temporary file after xx reties.
    Info    10:57:40.190  24 June 2021 20380 19436 internet DownloadTask HttpSendRequest failed, error: 12029
    Error   10:57:40.191  24 June 2021 20380 19436 pvsa CvAgent Failed to retrieve Nonce
    Error   10:57:40.191  24 June 2021 20380 17028 pvsa CvAgent FAILED_TO_AQUIRE_NONCE_MESSAGE
    Info    10:57:47.086  24 June 2021 20380 17028 dom Exchange Shutdown() 
    Info    10:57:47.086  24
This is a printer-friendly version of Article 312299 and may be out of date. For the latest version click CS312299