Applies To
- Windchill MPMLink 9.1 to 13.1
Description
- Open a part in MPSE and create a new branch, fails with error: Cannot create another Uses Occurrence for the given link
- Relevant phrase in method server log:
com.ptc.windchill.mpml.command.server.impl.NewBranchCommandDelegate wt.access.evaluation.report - "User" does not have New View Version permission for " Part - xxxxx, 3.5 (Design)" in Administrative Domain "Site, Organization - <OrgName>, Product - <Product name> /Default".
- Unable to perform the Editing > Subcontract to Plant action from BOM transformer due to error:
- Error while performing BOM Transformer:
ATTENTION: Secured Action. You do not have the necessary authorization for this operation. Contact your administrator if you believe you have received this message in error.
- Which ACL is needed for New Downstream Action
- New Downstream Branch action fails in BOM Transformer when there is already a Branch created
Checkout of downstream <Downstream_Part> is not allowed for current configuration. Equivalent association cannot be created.
This is a printer-friendly version of Article 49640 and may be out of date. For the latest version click CS49640