Article - CS77185
The Audit Change Notice task does not generate when a change notice task is completed in Windchill PDMLink 10.1
Modified: 20-Dec-2017
Applies To
- Windchill PDMLink 10.1 M010
Description
- If auditing is enabled and a business rule conflict exists in Windchill PDMLink, the Audit Change Notice workflow task is not generated and the Change Notice workflow does not complete
- Without the Audit Change Notice task, the user will not be able to view the business rule conflict
- If no business rule conflicts exist, the Audit Change Notice will be generated and the change can be released regardless of whether auditing is enabled or not.
- If the Audit Change Notice task is generated, the user may encounter the following error when attempting to complete the task:
This task cannot be displayed because you do not have permission to view the subject. Contact your project manager to increase your access rights.
- Method Server logs contains the following error:
wt.workflow.engine.WfActivity administrator - WfActivity.change state, exception caught Audit Change Notice, exception = A persistence error occurred.
(wt.pom.pomResource/0) wt.pom.PersistenceException: A persistence error occurred. System message follows:
Nested exception is: wt.pom.DatastoreException: A SQL error has occurred for the statement "INSERT INTO WorkflowVariableEventInfo(classnameA2A2,updateCountA2,administrativeLockIsNull,typeadministrativeLock,classnamekeydomainRef,idA3domainRef,classnamekeyeventReference,idA3eventReference,inheritedDomain,name,classnamekeyrecordReference,idA3recordReference,securityLabels,markForDeleteA2,value,varType,updateStampA2,createStampA2,modifyStampA2,idA2A2) VALUES ('wt.audit.eventinfo.WorkflowVariableEventInfo',1,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?)". Database system message follows:
Nested exception is: com.microsoft.sqlserver.jdbc.SQLServerException: String or binary data would be truncated.
OR
Nested exception is: java.sql.SQLException: ORA-01461: can bind a LONG value only for insert into a LONG column
This is a printer-friendly version of Article 77185 and may be out of date. For the latest version click CS77185