Article - CS58818

Pro/ENGINEER Wildfire TOOLKIT DLL causes Pro/ENGINEER Wildfire to exit, when initialized during launch, but not when initialized later.

Modified: 23-Nov-2016   


Applies To

  • Pro/ENGINEER and Creo Elements/Pro Wildfire 4.0 to Wildfire 5.0
  • Creo Parametric 2.0 to 3.0
  • Pro/ENGINEER Wildfire TOOLKIT
  • Creo Elements/Pro TOOLKIT
  • Creo Parametric TOOLKIT

Description

  • Pro/ENGINEER Wildfire TOOLKIT DLL causes Pro/ENGINEER Wildfire to exit, when initialized during launch, but not when initialized later.
  • If loading TOOLKIT DLL at the start of Pro/ENGINEER Wildfire, Pro/ENGINEER Wildfire will crash after showing the splash screen.
  • If registering the TOOLKIT DLL after the startup of Pro/ENGINEER Wildfire, it will get a running TOOLKIT DLL.
  • Content of std.err:
Warning: 2756 could not start message module 399929
Warning: 2756 could not start message module 399929
ERROR: could not initialize commn layer
  • Content of std.out:
Failed to initialize communications. Some features are disabled.
  • Exit happens only with users that have no administrator rights.
  • Issue happens only when launching TOOLKIT application during Pro/ENGINEER Wildfire startup, not when registering and launching later.
  • Trail file contains nothing than the welcome message.
This is a printer-friendly version of Article 58818 and may be out of date. For the latest version click CS58818