Article - CS442875
Unexpected behaviors occur in Visualization tab of Downstream structure for New Downstream objects starting from a WTPart (component or subassembly) displaying Image Link geometry in Visualization tab of Upstream structure in Windchill MPMLink
Modified: 18-Jun-2025
Applies To
- Windchill MPMLink 12.1 to 13.1
- Applicable ONLY in the scope of following Site Level preference set to yes:
Display representations from image associated EPM documents
Description
- Unexpected behaviors occur in Visualization tab of Downstream structure in BOM Transformer:
- Applies for WTParts (component or subassembly) displaying Image Link geometry in Visualization tab of Upstream structure (EBOM)
- Resulting in Downstream Structure as new objects (New Downstream Branch or New Downstream Part)
- Consequently impacts the BOM Transformation actions of Image Link WTParts such as Duplicate with or without Propagating, Copy/ Paste as New Branch or Copy/Paste as New part
- In above conditions, several unexpected behaviors can be observed in Visualization tab of MBOM as follows, based on the workflow how MBOM is created:
- Nothing visible (Visualization tab remains empty)
- Owner links are displayed (where Image links would have been expected)
- Visualization of components is not shown in correct location
This is a printer-friendly version of Article 442875 and may be out of date. For the latest version click CS442875