Article - CS441056
AIPLUGIN losing specification on cancel of the Image and try again to publish and sometimes gives error in AI-plugin in FlexPLM
Modified: 03-Apr-2025
Applies To
- FlexPLM 12.1
Description
- AIPLUGIN losing specification on cancel of the Image and try again to publish and sometimes gives error in AI-plugin.
- Steps to Reproduce:
Create a product with source and spec
1. Create an image page with initialize blank checkbox checked.
2. Download this file as xxx.ai and open in AI and checkout
3. Make some changes in the cell and check that it has a spec in Design Panel. Publish
4. Download the ai file again as xxx(1).ai and checkout Yes
5. Do not publish
6. Do not save and close this file
7. In FlexPLM UI check-in the image page from MYCHeckout items or Product>Documents
8. Download the ai file again as xxx(3).ai and checkout Yes
9. Check there is no specification shown in the Design Panel
10. It does not show the source
11. But when published it show the correct Specification in UI
- Works fine when ai file is downloaded from Product Panel in Design Suite.
This is a printer-friendly version of Article 441056 and may be out of date. For the latest version click CS441056