Windchill PDMLink: Unable to connect or register Windchill Server in Creo Parametric or Workgroup Manager
Modified: 19-Dec-2025
Applies To
- Creo Parametric 3.0 to 12.4
- Windchill PDMLink 9.1 to 13.1
- Creo+
- Windchill Workgroup Manager (WWGM)
- Mathcad
Description
- Unable to connect or register Windchill Server in Creo Parametric or Workgroup Manager
- Windchill PDMLink: Windchill server registration in Creo Parametric via Server Management window fails with error:
-
The Windchill server is unreachable. This may be due to the server being down or the location URL provided is incorrect.
-
- Windchill PDMLink: Unable to connect or register Windchill Server in Creo Parametric or Workgroup Manager
- Unable to register Windchill server with error:
-
Wildfire cache location %appdata%\PTC\Wildfire\.wf cannot be loaded
-
- Unable to get into the Workspace with no error and workspace does not load & gives blank screen
- Unable to register when trying to activate workspace
- Session premature exit upon registering the server
- Creo cannot load cache after running Windchill Workgroup Manager
- Error appearing after opening Creo or WGM Client cache located at <path> cannot be loaded
- Creo Parametric freezes or is not responding in Windchill connected session
- Registration of Windchill PDMLink server in Creo Parametric or in Workgroup Manager (WWGM) fails with error: Windchill authentication failed
- Following error is shown while registering a Windchill server in Creo Parametric or WWGM via Server Management
-
Invalid server location. Please change the Location field and try again 
-
- The Windows Security registration/authentication/credential window keeps popping up in both embedded and standalone browser
- Error
Invalid server name, Please change the "Name" field before you continue. - The cursor become spinning wheel when registering the Windchill server
- The following error is thrown when trying to connect to the Windchill Server if the config option windows_browser_type is set chromium_browser:
-
The Windchill server is unreachable. This may be due to the server being down or the location URL provided is incorrect
-
- Attempting to register or access the Windchill with server fails under the following circumstances:
- The Windchill server has a revoked SSL certificate
- The client is configured to use the embedded Chromium browser (config windows_browser_type chromium_browser)
- The client is configured for SSL CRL checking (config browser_enable_crl_check yes)
- Fails to display workspace item or check in CAD document with hanging status in Creo Parametric embed browser
- But in common space all can be displayed normally.
- Unable to log in Windchill after username and password are input in the dialogue in Creo Parametric
- The Workspace interface appears as version 10.2 style instead of the expected 13.0 style
- Clearing the cache of local Google Chrome did not resolve the issue
- Key words: integration, connect, connecting, connected, Windchill server, Server Management, register, Server not found, Server is not supported, location failed, Creo register URL
- User is unable to connect to SolidWorks and Workgroup Manager despite having the necessary access permissions in Windchill
- Error occurs while registering Windchill
wt.session.SessionUsersSPreLoginException: wt.licenseusage.licensing.LicensingException: Access is denied. You are not a registered Windchill user