Article - CS416076
Calculation result using Telcordia SR332 Issue 4 is different from expected in Windchill Risk and Reliability.
Modified: 21-Apr-2024
Applies To
- Windchill Risk and Reliability Team Edition (Formerly Relex) 12.0
Description
- Calculation result using Telcordia SR332 Issue 4 is different from expected.
- Comparing with Telcordia SR332 Issue 3, Calculation result using Telcordia SR332 Issue 4 is different.
- The result does not meet criteria: MTBF*Failure Rate=10^9
- Instead MTBF*Failure Rate=10^6