Article - CS40919
Windchill PDMLink: How to configure a custom Windchill worker to generate Creo View Representations of AutoCAD CAD Documents
Modified: 06-Nov-2025
Applies To
- Windchill PDMLink 9.0 to 13.1
- Windchill ProjectLink 9.0 to 13.1
- PTC Arbortext Content Manager 9.0 to 12.0
- Windchill PDM Essentials 10.1 to 12.0
- Pro/INTRALINK 8.x + 9.0 to 12.0
- Creo View Adapters 4.0 to 12.1
- Windchill Visualization Services (WVS)
- Autodesk AutoCAD
- Windchill plus
Description
- The ProductView Client views AutoCAD DWG format viewables natively, so there is no Creo View Adapter for AutoCAD available for converting the DWG format to any other Creo View viewable format
- Out-of-the-box, WVS will create a Representation using the CAD Document content as the viewable, without using a worker
- However, It is possible to configure the AutoCAD publishing class (com.ptc.wvs.server.publish.CadConvertACAD) to use a worker and it is up to you to decide whether the out-of-the-box AutoCAD publishing class can be customized enough to work for your business or if you need a truly customized solution
- This article provides sample methods for the Generic CAD worker that will enable you to create PDF viewable from AutoCAD DWG/DXF format
- How to convert AutoCAD format to PDF using Creo View Adapters?
- Does Creo View Adapter support base ACAD (AutoCAD) install?
- AutoCAD Publisher fails when trying to convert DWG files to PDF, when the file name has a SPACE or DOT
- Returned file does not exist
- How to create a new custom ShapeType?
- AutoCAD worker fails to generate thumbnail with error "No Thumbnail Created by Server for AutoCAD Representation"
- There is no PDF file in current dwg representation, is it possible to configure PDF output?
- Is it possible to setup a Worker to publish AutoCAD DWG, as PDF by setting up a AutoCAD-Worker?
- Are there any custom-worker or customizations involved in this process?
- What values should be set for PORT and HOST in the AutoCadWorkerstart.bat file?