Article - CS400791

SolidWorks workers sometimes exit prematurely post publish with Faulting application: sldworks.exe, Faulting module: baselibmtz.dll, Exception code: 0xc0000005 errors and then fail to start with DistributedCOM error

Modified: 06-Oct-2023   


Applies To

  • Creo View Adapters 9.1.0.0
  • Windchill PDMLink 12.0.2.2
  • Windchill Workgroup Manager
  • SolidWorks 2020
  • Publishing models with Japanese language components

Description

  • SolidWorks workers sometimes exit prematurely after publishing with the following reported in Windows Application Event Error:
Faulting application name: sldworks.exe, version: 28.5.0.78, time stamp: 0x5f9370c2
Faulting module name: baselibmtz.dll, version: 36.0.2021.71, time stamp: 0x60a63707
Exception code: 0xc0000005
Fault offset: 0x00000000000add25
Faulting process id: 0x1ca8
Faulting application start time: 0x01d9dbe803c65b43
Faulting application path: D:\SOLIDWORKS 2020\SOLIDWORKS\sldworks.exe
Faulting module path: D:\ptc\wgm\x86e_win64\obj\baselibmtz.dll
Report Id: d9943a6e-1fa3-4bab-8f63-5d85b87099b7
Faulting package full name:
Faulting package-relative application ID:
  • CAD worker logs show the following:
    • Worker Monitor:
[<date> <time>] Worker process started Ok.
[<date> <time>] Server connection has been closed.
[<date> <time>] Monitor Shutting down.
  • Worker Helper:
[<date> <time>] Passing $DONE$ message to server.
[<date> <time>] Received worker ready message.
[<date> <time>] Passing $JOB$ message to worker.
[<date> <time>] Passing $DONE$ message to server.
[<date> <time>] Received worker ready message.
[<date> <time>] Helper: Connection to server has been closed. Shutting down...
[<date> <time>] Worker helper shutting down.
  • Worker:
[<date> <time>] Closing WWGM file : COMPLETE
[<date> <time>] Downloading file using WWGM : COMPLETE
[<date> <time>] Recipe file: <path>/sw2pv.rcp
[<date> <time>] Source file: <file>.SLDPRT
[<date> <time>] Output file: <path>/<file>_SLDPRT.pvs
[<date> <time>] Processing Part : COMPLETE
[<date> <time>] Generating Output : COMPLETE
[<date> <time>] Generating thumbnail : COMPLETE
[<date> <time>] Closing WWGM file : COMPLETE
[<date> <time>] sw2pv Warning: Child lost connection to Parent
  •  Startup of Solidworks post exit sometimes fails with the following reported in Windows System Event Error:
DistributedCOM: The server {D134B411-3689-497D-B2D7-A27CB1066648} did not register with DCOM within the required timeout

 
This is a printer-friendly version of Article 400791 and may be out of date. For the latest version click CS400791