Article - CS398794

Unable to see or apply custom Structure View created in Downstream pane of BOM Transformer in Windchill MPMLink

Modified: 14-Nov-2024   


Applies To

  • Windchill MPMLink 12.1 to 13.0

Description

  • Unable to see or apply custom Structure View created in Downstream pane of BOM Transformer
  • Steps to reproduce:
    1. Create a new EBOM/Upstream Part in Product A and using BOM Transformer, create new MBOM/Downstream Part using New Downstream Part/Branch in Product B
      • Ensure that the EBOM Part and MBOM Part are in different contexts
    2. In the Downstream pane, click on Manage Structure Views
    3. Using Save as on Default View, create a new Structure View
      • When creating the View share it with Members of Context
      • image.png
    4. Add Columns like Source and Phantom Manufacturing Part
      • image.png
    5. Save the View and apply it
    6. Click the Dropdown to check the newly created View which is not shown in dropdown
      • Even if the View is active and applied from Manage Structure View, the View is not applied since the columns are not available
      • image.png
      • image.png
    7. If we go to MBOM Part's Details page and open it in BOM Transformer, the View is shown for the first time but if we change the View then it disappears again from the List
      • image.png