Article - CS392734
The dynamic mechanism analysis failed with error “Failed to initialize dynamics analysis” and "All velocity constraints can't be simultaneously satisfied." in Creo Parametric
Modified: 10-Mar-2024
Applies To
- Creo Parametric 7.0 to 9.0
Description
- The dynamic mechanism analysis failed. Message log shows:
- Failed to initialize dynamics analysis
- Assembly failed to connect. See file pmech_conn.txt for additional data.
- AnalysisDefinition1 failed.
- pmech_conn.txt file includes the following info:
- Error Diagnostics for Analysis/Assembly Failure
- All velocity constraints can't be simultaneously satisfied.
- The following velocity constraints can't be satisfied:
- 1) The following kinematic loop can't be closed: Ground - body1 - body3 - body2- Ground.
This is a printer-friendly version of Article 392734 and may be out of date. For the latest version click CS392734