Article - CS375111

Unable to start multiple method server instances in Windchill PDMLink

Modified: 03-Jun-2025   


Applies To

  • Windchill PDMLink 11.0 to 13.1

Description

  • Unable to start multiple method server instances
  • Only one MethodServer can be started after configuring Windchill Cluster although configuring several Method Servers
  • MethodServer crashed during startup
  • Server Manager reports:
ERROR [MethodServerMonitor] wt.manager.ServerManagerImpl - Start of MethodServer timed out.
ERROR [MethodServerMonitor] wt.server.manager.startup - Unable to launch 2 MethodServer instances wt.util.WTRemoteException: Unable to get server; nested exception is:
               (wt.manager.managerResource/3) wt.util.WTException: Start of MethodServer timed out.
  • The property wt.manager.cmd.MethodServer.debug.args of wt.properties is set to something like the below in wt.properties:
wt.manager.cmd.MethodServer.debug.args=-agentlib\:jdwp\=transport\=dt_socket,address\=7777,server\=y,suspend\=n
wt.manager.cmd.MethodServer.platform.java.args=-XX\:PermSize\=70m -XX\:MaxPermSize\=200m

 
This is a printer-friendly version of Article 375111 and may be out of date. For the latest version click CS375111