Article - CS373513

Windchill search does not return results correctly for iba related search

Modified: 06-May-2024   


Applies To

  • Windchill PDMLink 11.1

Description

  • Advance Search does not return correct results when using IBA
  • Search results consists parts which do not have the value entered in criteria of Advanced Search while searching for object with same IBA as criteria
  • Steps to reproduce :
  1. Create 2 soft types of wtpart (SOFTPARTA,SOFTPARTB).
  2. Create a re-usable attribute StringA where Internal Name,Display Name,Description and Logical Identifier has value as StringA
  3. Create global attribute on both soft types of wtpart using above re-usable attribute where Internal Name=STRINGA_INTERNAL and Display Name=STRINGA_DISPLAY
  4. Create some instances of soft type of part of the type SOFTPARTA where STRINGA_DISPLAY=goa
  5. On advanced search page add both soft types of wtpart:  SOFTPARTA,SOFTPARTB
  6. In QB criteria add STRINGA_DISPLAY=dsdsddsdd (any garbage value).
  7. Check if we get all instances of SOFTPARTA are listed in search results table
This is a printer-friendly version of Article 373513 and may be out of date. For the latest version click CS373513