The MTG & NPTH hole exported from Creo Parametric is shown as two holes in Cadence Allegro PCB, one is non-plated hole and the other one is pad, The pad hole is half the diameter of non-plated hole, how to adjust the diameter of pad?
Modified: 28-Jun-2022
Applies To
- Creo Parametric 8.0.0.0 to 8.0.5.0
Description
- To define nonmetallic mounting hole, assign MTG to ECAD_HOLE_TYPE and NPTH to ECAD_PLATING_STYLE for hole, then export IDX and import into Cadence Allegro PCB, it displays as two holes, the big one is non-plated hole, and the small one is shown as pad. The pad hole is half the diameter of non-plated hole. For example, if the diameter of non-plated hole is 10mm, the diameter of pad will be 5mm. How to adjust the diameter of pad?
- Create a simple hole and assign MTG to ECAD_HOLE_TYPE and NPTH to ECAD_PLATING_STYLE for hole, then export IDX
- Import the IDX file into Cadence Allegro PCB Design
- Select menu Setup > Design Parameters, check "Non-plated holes", you can show Non-plated hole
- Select menu Tools > Padstack > Modify Design Packstack, select the small circle > RMB > Edit, you can notice Regular Pad definition in TOP and BOTTOM