Article - CS367831
Unable to access the Windchill Application showing, "502 Bad Gateway Microsoft-Azure-Application-Gateway/v2" in web page
Modified: 29-Oct-2024
Applies To
- Windchill PDMLink 11.2 to 12.1
Description
- Not able to access the Windchill PDMLink
- Method sever logs shows "MethodServer ready" but Windchill application not starting
- 502 Bad Gateway Error after updating SSL Certificates
- Method Server fails to start
- Error showed in web page

- Error in mod_jk.log file:
[error] service::jk_lb_worker.c (1685): All tomcat instances failed, no more workers left [error] ajp_send_request::jk_ajp_common.c (1733): (tomcat1) connecting to backend failed. Tomcat is probably not started or is listening on the wrong port (errno=111) [error] ajp_service::jk_ajp_common.c (2817): (tomcat1) connecting to tomcat failed (rc=-3, errors=7, client_errors=0). [error] service::jk_lb_worker.c (1685): All tomcat instances failed, no more workers left