Article - CS357667
Error while running Navigate configurator with Navigate with Windchill Authentication
Modified: 24-Mar-2022
Applies To
- Windchill Navigate (formerly ThingWorx Navigate) 9.2
Description
Error while running Navigate configurator with Navigate with Windchill Authentication

Error:
{"module":"Stores","timestamp":"2021-11-25T02:56:59.727Z","level":"error","message":"Error reading certificate in p12 format:Error: Invalid openssl exit code: 1\n% openssl pkcs12 -info -in /u01/TWXKeystores/twx-truststore.jks -noout -maciter -nodes -passin file:/opt/ThingWorxFlow/modules/node_modules/ptc-windchill-connector/auth/connection/windchill-2way-ssl/v2/ea90c7daf050ee84ed5890238ec606b145f89ecc\n139882980919104:error:0D07207B:asn1 encoding routines:ASN1_get_object:header too long:crypto/asn1/asn1_lib.c:101:\n"}
{"module":"Windchill","timestamp":"2021-11-25T02:56:59.746Z","level":"error","message":"Response status code : 403 Windchill connector uses Windchill REST services (WRS). Please ensure your Windchill server has WRS"}
{"module":"Stores","timestamp":"2021-11-25T03:07:52.556Z","level":"error","message":"Error reading certificate in p12 format:Error: Invalid openssl exit code: 1\n% openssl pkcs12 -info -in /u01/TWXKeystores/twx-keystore.jks -noout -maciter -nodes -passin file:/opt/ThingWorxFlow/modules/node_modules/ptc-windchill-connector/auth/connection/windchill-2way-ssl/v2/6b670fbb6247831c5999bd4ee245082bf468fb64\n139717274699584:error:0D07207B:asn1 encoding routines:ASN1_get_object:header too long:crypto/asn1/asn1_lib.c:101:\n"}
Error:
{"module":"Stores","timestamp":"2021-11-25T02:56:59.727Z","level":"error","message":"Error reading certificate in p12 format:Error: Invalid openssl exit code: 1\n% openssl pkcs12 -info -in /u01/TWXKeystores/twx-truststore.jks -noout -maciter -nodes -passin file:/opt/ThingWorxFlow/modules/node_modules/ptc-windchill-connector/auth/connection/windchill-2way-ssl/v2/ea90c7daf050ee84ed5890238ec606b145f89ecc\n139882980919104:error:0D07207B:asn1 encoding routines:ASN1_get_object:header too long:crypto/asn1/asn1_lib.c:101:\n"}
{"module":"Windchill","timestamp":"2021-11-25T02:56:59.746Z","level":"error","message":"Response status code : 403 Windchill connector uses Windchill REST services (WRS). Please ensure your Windchill server has WRS"}
{"module":"Stores","timestamp":"2021-11-25T03:07:52.556Z","level":"error","message":"Error reading certificate in p12 format:Error: Invalid openssl exit code: 1\n% openssl pkcs12 -info -in /u01/TWXKeystores/twx-keystore.jks -noout -maciter -nodes -passin file:/opt/ThingWorxFlow/modules/node_modules/ptc-windchill-connector/auth/connection/windchill-2way-ssl/v2/6b670fbb6247831c5999bd4ee245082bf468fb64\n139717274699584:error:0D07207B:asn1 encoding routines:ASN1_get_object:header too long:crypto/asn1/asn1_lib.c:101:\n"}
This is a printer-friendly version of Article 357667 and may be out of date. For the latest version click CS357667