Article - CS348248

Navigate Configurator fails with error Failed to configure Flow connector PTC-Nav-Windchill-Connector in Thingworx Navigate 9.2

Modified: 29-Nov-2022   


Applies To

  • Windchill Navigate (formerly ThingWorx Navigate) 9.2 F000

Description

  • Navigate Configurator fails with error Failed to configure Flow connector PTC-Nav-Windchill-Connector.
  • Thingworx Foundation ,Thingworx Flow and Thingworx Navigate is installed successfully.
  • ThingWorxNavigateConfigurator.log reports following error while running Navigate Configurator to setup authentication options (Fixed or Windchill as authentication or SSO)
Configuring Navigate Connection to Windchill
Executing java
Configuring Flow connector
[09:54:22] - httpRequest useSSL = 1  

[09:54:22] Execute httpPost - URL:  https://ServerDomain:port/Thingworx/Subsystems/WorkflowSubsystem/Services/UpdateConnector?x-thingworx-session=true 

[09:54:23] - HTTP return code: 500

[09:54:23] Failed to configure Flow connector PTC-Nav-Windchill-Connector. Check Thingworx Application log for more information.
Problem running post-install step. Installation may not complete correctly
 Failed to configure ThingWorx Flow connector.
  • ApplicationLog.log reports following error:
[L: ERROR] [O: c.t.w.Subsystems] [I: ] [U: Administrator] [S: ] [P: ] [T: https-openssl-nio-8443-exec-45] Unable to Invoke Service UpdateConnector on WorkflowSubsystem : UpdateConnector failed for PTC-Nav-Windchill-Connector with status 400 Invalid connection.
2021-07-02 07:54:23.123+0000 [L: WARN] [O: c.t.w.BaseService] [I: ] [U: Administrator] [S: ] [P: ] [T: https-openssl-nio-8443-exec-45] Transaction has been marked as a failure for request /Thingworx/Subsystems/WorkflowSubsystem/Services/UpdateConnector
This is a printer-friendly version of Article 348248 and may be out of date. For the latest version click CS348248