Article - CS329998
Image associations to EPM Documents is unexpectedly not considered in Visualization tab of Process Plan Browser in Windchill MPMLink
Modified: 01-Jan-2024
Applies To
- Windchill MPMLink 11.2 to 12.0
Description
- Image associations to EPMDocument is unexpectedly not considered in Visualization tab of Process Plan Browser (PPB)
- Starting from Windchill MPMLink 11.2, below preference set to YES allows to generate representations from image association in WTPart Structures
Visualization >Dynamic Structure >Display representations from image associated EPM documents
- Visualization of WTParts in MAPSB / BOM Transformer will be also as expected after having been copied from Upstream, and pasted in Downstream structure
- Tree Picker accessed later from PPB also displays the correct Image representations in each child
- However, when a child (whose representation originally derives from an Image association) is allocated to an Operation, Visualization tab of PPB still displays the Owner representation
| Tree Picker before allocations | Visualization tab of Process Plan Browser after allocation of all components |
![]() | ![]() |
This is a printer-friendly version of Article 329998 and may be out of date. For the latest version click CS329998