Article - CS303366
Bounding Box Dimensions obtained when performing a Flat Pattern or a Flat Pattern Preview are not the ones expected when edges of Sheetmetal models are chamfered in Creo Parametric
Modified: 11-Jul-2022
Applies To
- Creo Parametric 1.0 to 6.0
Description
- Bounding Box Dimensions obtained when performing a Flat Pattern or a Flat Pattern Preview are not the ones expected when edges of Sheetmetal models are chamfered in Creo Parametric
- When a Chamfer is applied on Sheetmetal external edges, the dimensions of the Bounding Box are taken from the beginning of the Chamfer, instead of considering the end of the chamfer instead
- Bounding Box Dimensions obtained when performing a Flat Pattern or a Flat Pattern Preview are not the ones expected when edges of Sheetmetal models are rounds are added in Creo Parametric