Publish failure message "catia5_pv Error:2: Licensing Error" in Theorem adapter
Modified: 19-Jan-2026
Applies To
- Windchill PDMLink 10.2 to 13.0
- Creo View Adapters 1.0 to 12.0
- CATIA V5
- Theorem CADVerter
Description
- Failed jobs show the following error in Worker_#.log
catia5_pv MONITOR:: TS: catia5_pv : Summary code [-2] = [Licensing Error] catia5_pv Error:2: Licensing Error catia5_pv MONITOR:: TS: TS_CREOVIEW_RESTART_CONFIG env var not set - restart ignored catia5_pv MONITOR:: TS: catia5_pv_main <<<< end pv exit [1] return [-1] - Flexlm Server.log
(theorem) DENIED: "Catia5_ProductView" <User@hostID> (Licensed number of users already reached. (-4,342:10054 "")) - All publishing jobs for CATIA V5 objects failed with the error in worker logs:
Recipe file: <workersetup>/catia5_pv.rcp Source file: <SharedWorker>/###/<filename of CATIA V5 objects> Output file: <SharedWorker>/###/###.pvs Current Locale: English_United States.1252 Chord Height uses default catia5_pv Error:2: Licensing Error - Testing in batch mode with a local CATIA V5 file on the worker machine fails with the following error in command prompt window:
Catia5_Access ... Catia5_Access COMPLETE Cannot connect to license server system. The license server manager (lmgrd) has not been started yet, the wrong port@host or license file is being used, or the port or hostname in the license file has been changed. Feature: Catia5_ProductView Server name: ### License path: ###\###_###_License.lic;c:/flexlm/license.dat; FlexNet Licensing error:-15,10. System Error: 10061 "WinSock: Connection refused" ************************************************ * NOTE: License Validation Error * * Program terminating * * * ************************************************ Licence validation failure - program terminating System Information : Windows Translation completed with errors ... ... Please see summary/progress file