Article - CS282297

Windchill PDMLink: If the change notice tasks have sequences assigned and the first task is reopend by SetState action the CA workflow stucks on Sync robot

Modified: 06-Mar-2023   


Applies To

  • Windchill PDMLink 11.0 M030

Description

  • If the change notice tasks have sequences assigned and the first task is reopened by SetState action the CA workflow stuck on Sync robot
  • Steps to reproduce :
  1. Create Change Notice
  2. Create two tasks in this CN and assign them sequence
  3. Complete first task (task with sequence 1)
  4. Complete second task (task with sequence 2)
  5. Once both the tasks are completed reopen first task
    • perform SetState action on task#1 and change the state to Open
  6. New Change Activity workflow is triggered for this task
  7. However the sync on Change Notice Implementation robot from this process stuck and the workflow won't move ahead
This is a printer-friendly version of Article 282297 and may be out of date. For the latest version click CS282297