Article - CS279276
Windchill PDMLink: NX drawing BOM table (Parts List) displays incorrectly upon retrieval from workspace
Modified: 15-Mar-2018
Applies To
- Windchill PDMLink 10.2 M030 to 11.0 M030
- PTC Windchill Workgroup Manager
- Siemens NX
Description
- Rows of NX drawing BOM table (Parts List) loses information when retrieved from Windchill PDMLink
- Correct NX drawing BOM table (Parts List) before check in

- However after check in, in successive retrieval, the Parts List loses information from first row

Columns 'Description' and 'Part Number' in BOM table are mapped to Windchill attribute PTC_WM_PART_NAME and PTC_WM_PART_NUMBER respectively
- Use cases which leads to this scenario :
- Use Case 1:
- Create CAD document using "New CAD Document" action from workspace and associate it with WTPart
- Check it in without opening and saving it in CAD tool
- Use case 2:
- NX CAD Models are migrated into the system as Released and associated with WTParts as part of the migration process through Windchill Bulk Migrator
- Use Case 1: