Article - CS274444
Getting error Automation server can't create object when starting weblink application from Apache 2.4.28 and Internet Explorer as embedded browser
Modified: 08-Dec-2022
Applies To
- Creo Parametric 2.0 to 4.0
Description
- Getting error Automation server can't create object when starting weblink application from Apache 2.4.28 and Internet Explorer as embedded browser
- when weblink is started from an Apache 2.4.28, it fails with IE as the embedded browser for Creo whereas it is successful with Chromium, works fine when application is started from hard drive
- Automation server can’t create object at line var mGlob = pfcCreate("MpfcCOMGlobal");

- As a workaround, copy all the files locally by:
- creating a bat file which can copy the files into local drive
- setting the local path as home page in creo config.pro.
This is a printer-friendly version of Article 274444 and may be out of date. For the latest version click CS274444