Article - CS268893

Unable to create design review after upgrade from Windchill 10.2 M030 to 11.0 M030

Modified: 10-May-2018   


Applies To

  • Windchill PDMLink 11.0 M030 to M030-CPS11

Description

  • Design Review objects are missing after the re-host upgrade from Windchill 10.2 M030 to 11.0 M030 using Upgrade Manager
  • Design Review types are missing after Updates or Upgrades to Windchill 11.0 M030
Name
TypeContextEnabledType Missing?Lifecycle Template Missing?OIR Missing?Workflow Template Missing?
Design ReviewDesign ReviewSiteYesYYYY
Peer ReviewPeer ReviewSiteYesYYYY
Change ReviewReviewSiteYesYYYY
wt.folder.FolderException:
Object "null" must be assigned to a folder.
(wt.folder.folderResource/5) wt.folder.FolderException

com.ptc.windchill.upgrade.logging.UpgradeFrameworkLogger - Migrator FAILED: Load Change Management Lifecycle and Workflow
Load Change Management Lifecycle and Workflow templates failed.  See report for error labeled Error executing IncrementalUpdate Load Change Management Lifecycle and Workflow templates​
This is a printer-friendly version of Article 268893 and may be out of date. For the latest version click CS268893