Description

  • After restart Method server is not starting with error
  • After Build deployment Method Server not starting 
  • Method Server Crashed after installation of Creo View Adapter 8.1 on Server Side :
wt.method.server.startup.services  - Unable to start all managers. (wt.services.servicesResource/21) 
wt.services.ManagerException: Unable to start manager: "com.ptc.windchill.upgrade.instupghistory.service.DatabaseVersioningService" with implementation class: "com.ptc.windchill.upgrade.instupghistory.service.StandardDatabaseVersioningService" 
Nested exception is:wt.services.ManagerException: (com.ptc.windchill.upgrade.instupghistory.instupghistoryResource/2) 
com.ptc.windchill.upgrade.instupghistory.IUHException: The current install has not yet been updated by the update tool.  
Please run the update tool before attempting to launch the method server. Nested exception is: (com.ptc.windchill.upgrade.instupghistory.instupghistoryResource/2) 
com.ptc.windchill.upgrade.instupghistory.IUHException: The current install has not yet been updated by the update tool. Please run the update tool before attempting to launch the method server.
at com.ptc.windchill.upgrade.instupghistory.InstallAndUpgradeHistory.activateWorkingInstallation(InstallAndUpgradeHistory.java:325)     
at com.ptc.windchill.upgrade.instupghistory.service.StandardDatabaseVersioningService.initTransaction(StandardDatabaseVersioningService.java:136)     
at com.ptc.windchill.upgrade.instupghistory.service.StandardDatabaseVersioningService.performStartupProcess(StandardDatabaseVersioningService.java:110)
  • After installing CPS, Methodserver failed to be startup with error: 
    ERROR [main] wt.method.server.startup.services  - Failure to start manager com.ptc.windchill.upgrade.instupghistory.service.StandardDatabaseVersioningService wt.services.ManagerException: (com.ptc.windchill.upgrade.instupghistory.instupghistoryResource/2) com.ptc.windchill.upgrade.instupghistory.IUHException: The current install has not yet been updated by the update tool.  Please run the update tool before attempting to launch the method server.
    Nested Exception: (com.ptc.windchill.upgrade.instupghistory.instupghistoryResource/2) com.ptc.windchill.upgrade.instupghistory.IUHException: The current install has not yet been updated by the update tool.  Please run the update tool before attempting to launch the method server.
    	at com.ptc.windchill.upgrade.instupghistory.InstallAndUpgradeHistory.activateWorkingInstallation(InstallAndUpgradeHistory.java:330)
    	at com.ptc.windchill.upgrade.instupghistory.service.StandardDatabaseVersioningService.initTransaction(StandardDatabaseVersioningService.java:136)
    	at com.ptc.windchill.upgrade.instupghistory.service.StandardDatabaseVersioningService.performStartupProcess(StandardDatabaseVersioningService.java:110)
    	at wt.services.StandardManager.startup(StandardManager.java:460)
    	at wt.services.ManagerImplementation.startup(ManagerImplementation.java:363)
    	at wt.services.DefaultStartupHandler.startup(DefaultStartupHandler.java:112)
    	at wt.services.StandardManagerService.performStartupProcess(StandardManagerService.java:168)
    	at wt.services.StandardManager.startup(StandardManager.java:460)
    	at wt.services.StandardServicesHandler.start(StandardServicesHandler.java:44)
    	at wt.method.MethodServerMain.run(MethodServerMain.java:589)
    	at wt.method.MethodServerMain.main(MethodServerMain.java:358)

     