Article - CS255097
Error "Internal error: memory access violation" when saving new data to the workspace with Windchill Workgroup Manager for NX11
Modified: 10-Dec-2018
Applies To
- Windchill PDMLink 11.0 M020-CPS03 to M020-CPS11
- Windchill PDMLink 10.2 M030-CPS21
- Windchill Workgroup Manager 10.2 M030 CPS21
- Windchill Workgroup Manager 11.0 M020 CPS03, CPS10 and CPS16
- Unigraphics 11.0
- Not reproducible in NX 10
Description
Unable to save new data the workspace with NX11
- Trying to save to workspace fails with error:
Internal error: memory access violation
- The NX log (File > Help > Log file) throws the following:
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\ugui\no\ind\mb_callbacks.c" at line number 1596
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\ugui\no\ind\mb_menubar.c" at line number 1685
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\ugui\no\ind\uigblfunc.c" at line number 399
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\uginitint\no\ind\clink.c" at line number 767
&MACRO FOCUS CHANGE IN 1
&MACRO MESSAGE_BOX -2, Internal error: memory access violation
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\ugui\no\ind\mb_menubar.c" at line number 1685
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\ugui\no\ind\uigblfunc.c" at line number 399
>>>> O/S ERROR: signal 11 caught in file "o:\ugnx110\ip33\src\uginitint\no\ind\clink.c" at line number 767
&MACRO FOCUS CHANGE IN 1
&MACRO MESSAGE_BOX -2, Internal error: memory access violation
- Importing to workspace fails in NX 11
- The same actions succeed without issues in other CAD applications (i.e: CATIA, Solidworks) using the same Workgroup Manager release 10.2 M030 CPS21
- Siemens NX11 doesn't interact with Workgroup Manager
- No new parts can be created
- Workgroup Manager can communicate with Windchill if executed alone
- Additional messages found in the nx.._debug.log file within the cadapp folder:
E: T1998: uwgmapp: UWGM_ADAPTER: Error loading library . Exiting...
E: T1998: uwgmapp: UWGM_ADAPTER: Please verify the if .NET Framework 4.5.1 or newer is installed
- NX fails to open part from Workgroup Manager with error:
SOAP Client Error: Failed to open SOAP RPC call response stream
This is a printer-friendly version of Article 255097 and may be out of date. For the latest version click CS255097