Article - CS188743

Trying to modify an Operation where one of its attribute value has been deleted form the Legal Value List fails with Uncaught Exception on the Product Structure Browser in Windchill PDMLink 10.2

Modified: 16-Oct-2015   


Applies To

Windchill PDMLink 10.2 M020

Description

  • Trying to modify an Operation where one of its attribute value has been deleted form the Legal Value List fails with error on the Product Structure Browser:
Uncaught Exception!
(TypeError): 'value' is undefined
number: -2146823279
description: 'value' is undefined
  1. Create a String Attribute on Operation type with Legal Value List like 'A|B|C'
  2. Create a Process Plan with one Operation with value 'C' for the attribute created previously
  3. Access the Type Manager and Remove the value 'C' form the Legal Value List
  4. Access again the Process Plan and select the Operation
  5. Try to select another value and observe the error
This is a printer-friendly version of Article 188743 and may be out of date. For the latest version click CS188743