Article - CS187931

Reusable component from NX 9.0 Reuse Library can only be added once to an assembly while connected to Windchill PDMLink 10.2 datecode M020

Modified: 24-Oct-2014   


Applies To

  • Windchill PDMLink 10.2 datecode M020
  • Workgroup Manager 10.2 datecode M020
  • Unigraphics NX 9.0.3

Description

  • Reusable component from NX 9.0 Reuse Library can only be added once to an assembly while connected to Windchill PDMLink 10.2 datecode M020
  • Fail to add another variant of Family Table in assembly that has other instances of the same FT
Error:

The following parts cannot be added as components C:/<dir path>/model.prt. Another version of the same part is already loaded C:/<dir path>/model.prt
This is a printer-friendly version of Article 187931 and may be out of date. For the latest version click CS187931