Article - CS179457
Update_tool command fails with error Class not registered in modelRegistry.properties while updating Windchill PDMLink
Modified: 11-Mar-2025
Applies To
- Windchill PDMLink 9.1 to 13.0
Description
- Task Initialize Upgrade failed during UpgradeManager
- Update_tool command fails with error "Class not registered in modelRegistry.properties" while updating Windchill
- Running CPS PSI fails with error "Class not registered in modelRegistry.properties"
- Windchill Method Server failed to start with error "Class not registered in modelRegistry.properties"
- Error reported:
ERROR[main] com.ptc.windchill.upgrade.statemachine.UpgradeFrameworkStateMachine - State execution encountered exception: ReportWriterUpgradeState(Upgrade Database Schema) wt.util.WTException: wt.util.WTException: (wt.introspection.introspectionResource/9) wt.introspection.InfoNotFoundException: Class not registered in modelRegistry.properties: ****. Nested exception is: (wt.introspection.introspectionResource/9) wt.introspection.InfoNotFoundException: Class not registered in modelRegistry.properties: ****. Nested exception is: wt.util.WTException: (wt.introspection.introspectionResource/9) wt.introspection.InfoNotFoundException: Class not registered in modelRegistry.properties: ****. Nested exception is: (wt.introspection.introspectionResource/9) wt.introspection.InfoNotFoundException: Class not registered in modelRegistry.properties: ****. at wt.introspection.WTIntrospector.loadInfo(WTIntrospector.java:690) at wt.introspection.WTIntrospector.getClassInfo(WTIntrospector.java:317) at wt.introspection.BaseTableInfo.accumulateColumns(BaseTableInfo.java:127)
- Steps to reproduce:
- Run the PSI with site modified option after putting the modelRegistry.properties file under the wtsafearea
- Run the PSI with complete option
- Run the update tool command