Windchill Workgroup Manager 10.1 M040 Functional Patch and Support for Additional CAD Versions (12-June-2014)

Modified: 07-Aug-2024   


Applies To

  • Windchill ProjectLink 10.1 M040
  • Pro/INTRALINK 8.x + 10.1 M040
  • Windchill PDMLink 10.1 M040
  • PTC Windchill Workgroup Manager
  • CATIA V5-6R 2014
  • Inventor 2014
  • NX 6.0
  • SolidWorks 2014

Description

  • A patch for the 10.1 M040 release of the Windchill Workgroup Manager is available (as of 12-June-2014)
  • The patch resolves functional issues and adds support for the following CAD Versions:
    • Inventor 2014
    • SolidWorks 2014
    • CATIA V5-6R2014
    • NX 6.0 (formerly Unigraphics/UG-NX)
  • See the following articles for additional detail regarding issues resolved in the patches:
    • CS159648 - Add support for the following CAD Versions in a 10.1 M040 WWGM Temp Patch: Solidworks 2014, Catia V5-6R2014
    • CS174254 - Add support for NX 6 in a 10.1 M040 WWGM Temp Patch
    • CS169189 - Link between Inventor model and Excel worksheet is broken after performing Import to WorkSpace
    • CS166086 - Performance issues when retrieving NX assembly from Windchill PDMLink
    • CS160031 - After importing AutoCAD dwg drawing files, some EPM Documents list a different File Name in the Information Page Content report
    • CS159884 - SolidWorks exits during the publication of documents with File Synchronization in Windchill PDMLink 10.1 M040
    • CS159107 - NX 8.5 command "Save Work Part Only" does not work with Windchill PDMLink 10.1
    • CS174261 - "Express Mode" is not available in Inventor 2014 File Open Options when Inventor is integrated with the Windchill Workgroup Manager
    • CS152747 - SolidWorks and Windchill Workgroup Manager 10.1 client hang after "SolidWorks > File Open from Windchill"
    • CS157127 - CATIA V5 hangs when connected to Windchill 10.1 M040 while updating a linked model using the option "Update all"
    • CS156969 - Poor performance for the save action in Solidworks when being connected to Windchill Workgroup Manager
    • CS156805 - After an upgrade to Windchill 10.1 M040, upload for new ECAD "content definition" fail with "For input string" error in Conflict management pop-up
    • CS154982 - AutoCAD Inventor MDT links are broken when AutoCAD Inventor is in use with the Windchill Workgroup Manager
    • CS174262 - Objects are loaded from outside the Windchill Local Directory and Read Only Area on switch to design mode
    • CS174263 - Incorrect filesize is shown in attachment table for large size attachment files
    • CS152792 - CATIA hangs when opening assemblies using the 10.1 wgmclient.ini preference "open.assembly.cgrs=Yes"
    • CS151949 - Windchill Workkgroup Manager 10.1 for CATIA V5 crashes on Cache cleaning step
    • CS148895 - With manged Read Only Area configuration, opening a CATProduct from Windchill server will download all files from Windchill including the files that are located in the Manged Read Only Area in Windchill PDMlink 10.1
    • CS174398 - When selecting Save All when multiple drawings are modified in session causes the other drawings to become out of sync
    • CS143367 - Windchill Workgroup Manager becomes unresponsive or may exit prematurely performing various operations
    • CS142757 - Line Number value in WTPart structure is lost after CAD assembly is modified in Windchill PDMLink 10.1 M040
    • CS141853 - Attempting to auto attach large content files fails with error message: “Failed to copy to secondary workspace directory”
    • CS134856 - Each WTPart represented in the CATDrawing as child of the CATProduct has a link to the assembly CATDrawing
    • CS135131 - Windchill Menu Missing in Windchill Workgroup Manager integrated CATIA V5 Session After Installing Dassault Hotfix
    • CS174403 - After launch of Inventor, the workspace location of local project file is overwritten, it is set to the Windchill Workspace directory. Only the Inventor workspace of the default project should be set to the Windchill Workspace directory
    • CS133804 - Add support for the following CAD Versions in a 10.1 M040 WWGM Patch: AutoCAD 2014 Inventor 2014 CATIA V5-6R2013 Creo Illustrate 3.0
    • CS132903 - Windchill 10.1 Workgroup Manager for CATIA V5 hangs (gets non-responsive) during the metadata propagation when a CATProduct containing components migrated from Windchill 9.1 is opened in CATIA V5 session
    • CS131140 - CATAnalysis files cannot be opened with GAS and GPS licenses pulled from "Shareable Products" in CATIA connected mode
    • CS129590 - Client cache processing performance is poor when the user is members of many contexts (>5000)
    • CS127116 - Workgroup Manager for Creo Elements/Direct Modeling doesn't correctly update the local cache when it is closed
    • CS130913 - Check In of an assembly fails "Baseline "wt.epm.workspaces.EPMCheckpoint:######" is currently being modified by another user. The operation cannot be completed."
    • CS125184 - In Windchill PDMLink 10.1, manual Defined Part Number is ignored while Auto-numbering is enabled
    • CS124709 - Synchronize of objects in a linked session takes longer in Windchill PDMLink 10.1 M040 than 10.1 M010
    • CS124708 - Add to Workspace in a linked session takes longer in Windchill PDMLink 10.1 M040 than 10.1 M010
    • CS124343 - Performance is slow when checking in a new Parts Library component when working with many objects in workspace
    • CS122488 - Some CAD Documents are created with Document Category "OTHER" when using the Import to Workspace function in Winchill PDMLink 10.1
    • CS130908 - The Methodserver JVM crashes with hs_err_pid*.log reference bcEscapeAnalyzer.cpp and Check In fails with "transaction's client id does not match server transaction id (NO_SERVER_TRANSACTION_ID)"
    • CS120813 - SLDWORKS.exe process is not always stopped after a successful Import to Workspace in a SolidWorks Windchill Workgroup Manager 10.1
    • CS174425 - Child components are added multiple times to an assembly structure after opening the assembly multiple times from Workspace without closing the NX session
    • CS119237 - Slow Check In of one object from a big workspace in Workgroup Manager Creo Elements/Direct Modeling 10.1
    • CS102658 - Unable to retrieve windchill system attributes to a CATIA Drawing on check-out to workspace. But we are able to retrieve attributes like Name, Revision, Iteration, State
    • CS174429 - Import or Generate data with check in option selected fails during upload when the object has a large attachment >2GB.  Upload also fails if a >2GB file is attached via "Edit attachment"
    • CS81793 - Import to Workspace or Save to Workspace performance is poor and SolidWorks may exit prematurely during the operation
    • CS69352 - Creo Parametric 1.0 M030 hangs if the local PDMLink Cache Size limit is exceeded
    • CS174430 - Save to WS action from AutoCAD for file opened from outside WLD, closes other files opened in AutoCAD session even if those are in modified state. No message is displayed to user about closing of files
    • CS132764 - Locally modified files disappear from the local cache while working in Creo or Windchill Workgroup Manager and Windchill PDMLink
  • Patch also includes fixes for the following provided in previous patches.  See the following for additional detail:
    • CS141139 - Windchill Workgroup Manager 10.1 M040 Performance and Functional Patch (29-Aug-2013)
    • CS155369 - Windchill Workgroup Manager 10.1 M040 Functional Patch (17-Dec-2013)
    • CS133804 - Windchill Workgroup Manager 10.1 M040 Functional Patch and Support for Additional CAD Versions (6-Jan-2014)
This is a printer-friendly version of Article 160577 and may be out of date. For the latest version click CS160577