Article - CS145803

WTParts fail to build with error "Nothing to build." in Windchill PDMLink

Modified: 05-Mar-2024   


Applies To

  • Windchill PDMLink 9.0 to 11.1
  • Windchill ProjectLink 9.0 to 11.1
  • Pro/INTRALINK 8.x + 9.0 to 11.1
  • Creo Parametric 1.0 to 5.0
  • Migrated data from older Windchill releases:
    • ​Pro/ENGINEER CAD Documents migrated from pre-Windchill 8.0 releases
    • 3rd Party CAD Documents migrated from Pre Windchill 10.0 releases
  • PTC Windchill Workgroup Manager

Description

  • WTParts fail to build from EPM Documents with errors
Nothing to build

com.ptc.windchill.uwgm.cadx.build.BuildProcessor <user> - BuildProcessor.redirectBuildAction :: (wt.build.buildResource/1) wt.build.NoRulesToBuildException: Nothing to build.  No rules were found to build this "CAD Part  - <object>, <version>"
  • WinDU EPMDocumentVerifiedColumnCheck task reports some EPM Documents whose verified flag needs to be set to true:
ERROR|Found 249623 EPMDocuments where verified flag needs to be set to true
  • CAD Documents migrated from old Windchill releases fail to build associated WTPart structure
  • Build from structure fails
  • Set for build action is greyed out or not available for associated parts
  • Part structure is not built after CAD Document check in
  • During Pre-Load Validation of EPMBuildHistory, Windchill Bulk Migrator returns:
    • Invalid value of verified flag for participating EPMDocument in build process.
  • Bulk Build Utility may fail to build WTPart for cad documents having  failed feature/un-regenerated failed assembly ,unverified document assemblies will not build associated part structure , refer CS105104 