Article - CS145803
WTParts fail to build with error "Nothing to build." in Windchill PDMLink
Modified: 05-Mar-2024
Applies To
- Windchill PDMLink 9.0 to 11.1
- Windchill ProjectLink 9.0 to 11.1
- Pro/INTRALINK 8.x + 9.0 to 11.1
- Creo Parametric 1.0 to 5.0
- Migrated data from older Windchill releases:
- Pro/ENGINEER CAD Documents migrated from pre-Windchill 8.0 releases
- 3rd Party CAD Documents migrated from Pre Windchill 10.0 releases
- PTC Windchill Workgroup Manager
Description
- WTParts fail to build from EPM Documents with errors
Nothing to build
com.ptc.windchill.uwgm.cadx.build.BuildProcessor <user> - BuildProcessor.redirectBuildAction :: (wt.build.buildResource/1) wt.build.NoRulesToBuildException: Nothing to build. No rules were found to build this "CAD Part - <object>, <version>"
com.ptc.windchill.uwgm.cadx.build.BuildProcessor <user> - BuildProcessor.redirectBuildAction :: (wt.build.buildResource/1) wt.build.NoRulesToBuildException: Nothing to build. No rules were found to build this "CAD Part - <object>, <version>"
- WinDU EPMDocumentVerifiedColumnCheck task reports some EPM Documents whose verified flag needs to be set to true:
ERROR|Found 249623 EPMDocuments where verified flag needs to be set to true
- CAD Documents migrated from old Windchill releases fail to build associated WTPart structure
- Build from structure fails
- Set for build action is greyed out or not available for associated parts
- Part structure is not built after CAD Document check in
- During Pre-Load Validation of EPMBuildHistory, Windchill Bulk Migrator returns:
- Invalid value of verified flag for participating EPMDocument in build process.
- Bulk Build Utility may fail to build WTPart for cad documents having failed feature/un-regenerated failed assembly ,unverified document assemblies will not build associated part structure , refer CS105104
This is a printer-friendly version of Article 145803 and may be out of date. For the latest version click CS145803