Article - CS131820
Publishing on fails on LiveCycle server with error code 109 with Creo View Adapter
Modified: 02-Nov-2020
Applies To
- Windchill PDMLink 9.1 to 11.2
Description
- Publishing of Office documents fails on LiveCycle server with error code 109
- Error in JBOSS server log:
2013-06-17 09:45:38,245 INFO [STDOUT] (ProcessResource@47007bcd(name=pdfgen.exe,pid=0) Output Reader)
ERROR: API = ReadFile(1)
2013-06-17 09:45:38,250 INFO [STDOUT] (ProcessResource@47007bcd(name=pdfgen.exe,pid=0) Output Reader)
ERROR CODE = 109
MESSAGE = The pipe has been ended.
2013-06-17 09:45:38,253 WARN [com.adobe.service.ProcessResource]
(ProcessResource@47007bcd(name=pdfgen.exe,pid=0) Error Reader)
ALC-BMC-001-024: Service PDFMakerSvc: Process ProcessResource@47007bcd(name=pdfgen.exe,pid=0) terminated abnormally with error code {3}
ERROR: API = ReadFile(1)
2013-06-17 09:45:38,250 INFO [STDOUT] (ProcessResource@47007bcd(name=pdfgen.exe,pid=0) Output Reader)
ERROR CODE = 109
MESSAGE = The pipe has been ended.
2013-06-17 09:45:38,253 WARN [com.adobe.service.ProcessResource]
(ProcessResource@47007bcd(name=pdfgen.exe,pid=0) Error Reader)
ALC-BMC-001-024: Service PDFMakerSvc: Process ProcessResource@47007bcd(name=pdfgen.exe,pid=0) terminated abnormally with error code {3}
This is a printer-friendly version of Article 131820 and may be out of date. For the latest version click CS131820