Article - CS125234
No class of tolerance is defined for Hole G9 in the Tolerance Table file .ttl and when inserting toerlance in drawing it displayes/showes a wrong value in Pro/ENGINEER, Creo Elements/Pro and Creo Parametric
Modified: 11-May-2017
Applies To
- Pro/ENGINEER and Creo Elements/Pro Wildfire to Wildfire 5.0
- Creo Parametric 1.0 to 2.0
Description
- No class of tolerance is defined for Hole G9 in the Tolerance Table file .ttl and when inserting toerlance in drawing it displayes/showes a wrong value.
- Warning : The table Defaults has no tolerance value for dimension d#
- Some values are not defined inside the tolerance tables inside Pro/ENGINEER, for example inside the shaft_f some values are filled with "\"-" Instead of Numerical Values.
- For example for a Shaft dimension of 420mm, a11 should be (-1.65 and -1.9) and c11 should be ((-0.48 and -0.84)depending on the ISO286 Table. but Pro/ENGINEER give a wrong value as for a11 (-1.5 and -1.9) and c11 (-0.44 and -0.84)