In Windchill ProjectLink 10.0 M030, "%Work Complete" can not be set to 100 in "Track Work for Selected Assignments" wizard when the Microsoft Internet Explorer language is "Chinese(Simplified, PRC) [zh-CN]"

Modified: 27-Dec-2012   


Applies To

  • Windchill ProjectLink 10.0 M030, M040
  • Windchill ProjectLink 10.1 F000, M010, M020
  • Microsoft Internet Explorer all suppported release

Description

  • %Work Complete can not be set to 100 in Track Work for Selected Assignments wizard when the Microsoft Internet Explorer language is Chinese(Simplified, PRC) [zh-CN]
  • It prompts following error on Windchill UI:
Attention: "unit" should be number
  • Following error prompted in MethodServer log:
ERROR : com.ptc.projectmanagement.assignment.resource.processors.EditMultipleAssignmentTrackWorkFormProcessor contextadmin - java.lang.NumberFormatException: For input string: ""
ERROR : com.ptc.jca.mvc.controllers.WizardController contextadmin - java.lang.reflect.InvocationTargetException: java.lang.reflect.InvocationTargetException
    at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
    at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)
    at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
    at java.lang.reflect.Method.invoke(Method.java:597)