Article - CS439214
Windchill Workgroup Manager for SOLIDWORKS: Subassembly is unexpectedly marked as modified while saving Top Assembly
Modified: 11-Mar-2025
Applies To
- Windchill PDMLink 12.1.2.0 to 13.1
- Windchill Workgroup Manager 13.1.0.0 and earlier
- SolidWorks 2023 and earlier version
Description
- When opening a top-level assembly in lightweight mode, sub-assemblies are being modified automatically and appear in the Check Out on Fly conflict window
- Steps to reproduce:
- Set Windchill PDMLink Server Preference: Independently modify instances to Yes
- Open Multilevel Assembly with subassembly containing FT parts configurations in Lightweight mode
- Perform Check-Out for part configurations in the top and sub-assembly
- In SOLIDWORKS, save the top assembly, the Conflict window appears