Article - CS412661
A NX component will be opened in a new window unexpectedly in Windchill PDMLink
Modified: 31-Oct-2025
Applies To
- Windchill PDMLink 12.1 to 13.1
- Windchill Workgroup Manager 13.0.0.0 to 13.0.1.1
- Windchill Workgroup Manager 13.1.0.0 to 13.1.0.1
- NX
Description
- In Windchill Workgroup Manager 13.0.0.0 and NX 2212, when opening an assembly with Structure Only and then opening it from model tree, a NX component will be opened in a new window unexpectedly.
- The File Name this problematic component has been renamed via switching upper/lower case from common space before.
- The issue does not occur if the file name of components is extended or completely changed.
- Steps to reproduce:
- create a part with file name aaa.prt and save to ws
- create an assembly, add the part and save to ws
- checkin the assembly and part
- remove all of the objects from ws and clear cache
- rename the file name of the part from aaa.prt to AAA.prt
- make sure the load option of NX is Structure Only
- open the assembly from common space
- in model tree, select the top assembly, right click Open > Assembly
- go to the Windows pull-down menu in NX, the renamed component could be seen.
This is a printer-friendly version of Article 412661 and may be out of date. For the latest version click CS412661