Article - CS223105

Creo View Adapters 3.0: Creo Worker fails to authenticate server when GS Worker Daemon is started as a Windows service, error “Failed to register Windchill server... -15”

Modified: 16-Jun-2023   


Applies To

  • Creo View Adapters 3.0 M032
  • Windchill PDMLink 10.0 to 12.1

Description

  • When the GS Worker Daemon is set to run as a service, a file sync Creo worker fails to connect to the Windchill server with error
    • Failed to register Windchill server "https://<hostname>/Windchill" "publish6526738819666916719tmp" - -15
  • ​Simultaneously, uwgm.log file will read:
    • E: T0f1c: uwgm.session0.8: ServerCache: UwgmServerCache_i::makeFirstServerConnection FAILED
    • E: T0f1c: uwgm.session0.8: ServerCache: UwgmServerCache_i::makeFirstServerConnection: CIP Exception: SOAP Client Error: Failed to finish writing SOAP call request.
This is a printer-friendly version of Article 223105 and may be out of date. For the latest version click CS223105