Changing the workspace in a session of Creo Parametric will change the workspace in all currently running sessions

Modified: 19-May-2025   


Applies To

  • Creo Parametric 3.0 to 9.0.0.0
  • Windchill PDMLink 10.2 to 12.0

Description

  • Creo Parametric cache sharing works as follows:
    1. A Windchill server is registered and is online in a Creo session, another Creo session is also running and is using the same PTC_WF_ROOT, PTC_WF_CACHE and CREO_AGENT_HOME environment (cache directories)
    2. If the Workspace or Server entries are changed (eg. change  of active Workspace or go offline, no server), the changes in registry is now applied to all running sessions of Creo that are using the same cache directories
  • Change in one connected session of Creo Parametric, changes all other opened sessions that are using the same cache directories
  • Unable to use different workspaces while concurrently running multiple Creo Parametric sessions while connected to the same Windchill PDMLink 
  • Register server in one Creo session, the server will be auto registered when starting another Creo session
  • Is it possible to register server in one Creo session, and another Creo session is on "no server" mode
  • When the same cache is used, the second Creo process is unresponsive