Article - CS362311

UpgradeManager fails in Executive Server Migrators at phase Update "Tablayout" preference in Windchill PDMLink

Modified: 29-Jan-2024   


Applies To

  • Windchill PDMLink 12.0 to 12.1

Description

  • UpgradeManager fails with below errors :
  • In UpgradeManager-XXXX-log4j.log :
FATAL [main] com.ptc.windchill.upgrade.updates.UpdateRunner - com.ptc.windchill.upgrade.updates.UpdateExecutionException: Error executing IncrementalUpdate Update "TabLayout" preference (#775308897-1549894667760-733957003-1-0-0-127)
Nested exception is: (com.ptc.windchill.upgrade.updates.directives.directivesResource/39) com.ptc.windchill.upgrade.updates.DirectiveExecutionException: Method server code wt.partstructurebrowser.migrator.TabLayoutPreferenceMigrator.runMigration failed.  See nested exception for details
Nested exception is: (wt.pom.pomResource/10) wt.pom.PersistenceException: A commit cannot be done when a rollback is in progress.  The following is the rollback stacktrace.
    ROLLBACK: java.base/java.lang.Thread.getStackTrace(Thread.java:1602)
  • In MethodServer.log :
javax.naming.NamingException: [LDAP: error code 1 - 000004DC: LdapErr: DSID-0C0907E9, comment: In order to perform this operation a successful bind must be completed on the connection
This is a printer-friendly version of Article 362311 and may be out of date. For the latest version click CS362311