Article - CS159196

Checkin fails in Windchill PDMLink 10.2 with error "A datastore uniqueness constraint violation has occurred on the following objects. Part Usage - wt.part.WTPartUsageLink:xxxxx"

Modified: 14-Mar-2014   


Applies To

  • Windchill PDMLink 10.2 M010
  • Windchill Workgroup Manager
  • Autodesk Inventor 2013

Description

  • Check In fails with error when checking in a modified CAD assembly where an assembly component is replaced and WTPart Find or Line Number Attributes are driven from CAD via preferences EPM Service Preferences > Build Service Perferences > Find Number Attribute or Line Number Attribute
A datastore uniqueness constraint violation has occurred on the following objects. Part Usage - wt.part.WTPartUsageLink:xxxxxx

Sample error message