Remote session using Axeda Desktop Viewer 6.9.215 gets disconnected if AutoAccept setting in Axeda Desktop Server is 30 seconds

Geändert: 30-Jul-2018   


Betrifft

  • Axeda - Connectivity 6.9.1

Beschreibung

  • Remote session using Axeda Desktop Viewer 6.9.215 gets disconnected if AutoAccept setting in Axeda Desktop Server is 30 seconds
  • Right click Axeda Desktop Server system tray icon on the asset and select Admin Properties
  • Ensure that Query on incoming connection is enabled with a Timeout of 30 seconds
Axeda Desktop Server Admin properties
  • Start a remote session using Axeda Desktop Viewer 6.9.215
  • Query window is displayed with a 30 second countdown timer
  • After 30 seconds the connection ends with the message:
Server closed connection
-The server running as application doesn't have permission to unlock screen.
-Manually closed
-Network disconnected
-Server refused connection
  • Other viewer versions work as expected
  • Timeout value of 10 seconds work fine even with Viewer 6.9.215