技术文章 - CS446737
在 Windchil PDMLink 13.0.2.5 中停止 Windchill 需要很长时间
已修改: 19-Jun-2025
适用于
- Windchill PDMLink 13.0.2.5
说明
- 使用 wincomplm 停止 Windchill 需要很长时间
- 线程转储显示停止 wincomplm 需要时间
at com.wincomplm.wex.deploy.utils.NmStandardServiceHelper.isLoaded(Unknown Source)
at com.wincomplm.wex.deploy.listeners.WexActionsDeployListener.onTerminate(Unknown Source)
at com.wincomplm.wex.kernel.impl.manager.WexKernelManager.onTerminated(Unknown Source)at com.wincomplm.wex.kernel.impl.manager.WexKernelPackage.terminate(Unknown Source)
at com.wincomplm.wex.kernel.impl.tree.TreeNode.M(Unknown Source)
at com.wincomplm.wex.kernel.impl.tree.TreeNode.M(Unknown Source)
at com.wincomplm.wex.kernel.impl.tree.Tree.remove(Unknown Source)
at com.wincomplm.wex.kernel.impl.manager.WexKernelManager.unload(Unknown Source)
at com.wincomplm.wex.kernel.impl.manager.WexKernelManager.performShutdownProcess(Unknown Source)
- locked <0x0000000084e35f18> (a com.wincomplm.wex.kernel.impl.manager.WexKernelManager)