技术文章 - CS403095

更改 ThingWorx 端口后,验证 ptc-windchill-integration-connector 的连接服务失败

已修改: 26-Oct-2023   


注意:本文已使用机器翻译软件翻译,以方便非英语客户阅读。但翻译内容可能包含语法错误或不准确之处。请注意, PTC对本文所含信息的翻译准确性及使用后果不承担任何责任。请在 此处 查看本文的英文原始版本以便参考。有关机器翻译的更多详情,请单击 此处
感谢您告诉我们。我们将尽快审阅此译文。

适用于

  • Windchill Navigate (formerly ThingWorx Navigate) 9.0 to 9.4.0

说明

  • 更改 ThingWorx 端口后,验证 ptc-windchill-integration-connector 的连接服务失败
  • ApplicationLog.log 中的错误
[L: ERROR] [O: c.t.w.Things] [I: ] [U: <username>] [S: ] [P: ] [T: https-openssl-nio-443-exec-2] Unable to Invoke Service : No Integration Runtime Connected, Contact Administrator for Further Information
  • IntegrationRuntime.log 中出现错误
[Client-EndpointMonitor-76] ERROR c.t.c.c.e.ClientCommunicationEndpoint - Refilling connections on [endpoint 677, uri: wss://<server>:<port>/Thingworx/WS] failed : timeout waiting for websocket handshake to complete
[Client-EndpointMonitor-76] ERROR c.t.c.c.e.ClientCommunicationEndpoint - Exception refilling connections was:
java.util.concurrent.TimeoutException: timeout waiting for websocket handshake to complete
	at com.thingworx.communications.client.connection.netty.NettyClientConnectionFactory$HandshakeCompletionNotifier.await(NettyClientConnectionFactory.java:693)
	at com.thingworx.communications.client.connection.netty.NettyClientConnectionFactory.createConnection(NettyClientConnectionFactory.java:398)
	at com.thingworx.communications.client.endpoints.ClientCommunicationEndpoint.refillConnections(ClientCommunicationEndpoint.java:230)
	at com.thingworx.communications.common.endpoints.monitor.ConnectivityMonitorTask.dutyCycleOn(ConnectivityMonitorTask.java:159)
	at com.thingworx.communications.common.endpoints.monitor.ConnectivityMonitorTask.run(ConnectivityMonitorTask.java:306)
	at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
	at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
	at java.base/java.lang.Thread.run(Thread.java:834)


这是文章 403095 的 PDF 版本,可能已过期。最新版本 CS403095