技术文章 - CS399203

Windchill PDMLink 中的 PSI 出现 OCU 错误“ORA-12514,TNS:监听器当前不知道连接描述符中请求的服务”

已修改: 03-Oct-2024   


注意:本文已使用机器翻译软件翻译,以方便非英语客户阅读。但翻译内容可能包含语法错误或不准确之处。请注意, PTC对本文所含信息的翻译准确性及使用后果不承担任何责任。请在 此处 查看本文的英文原始版本以便参考。有关机器翻译的更多详情,请单击 此处
感谢您告诉我们。我们将尽快审阅此译文。

适用于

  • Windchill PDMLink 11.0 to 13.0

说明

  • PSI 对 OCU 失败, OCU_PtcInstall.log中出现错误
Failed to create Windchill database user dbuser 
DEBUG  xxxx-xx-xx xx:xx:xx - SQL STATE: 08006 
DEBUG  xxxx-xx-xx xx:xx:xx - CODE: 12514 
DEBUG  xxxx-xx-xx xx:xx:xx - MESSAGE: Listener refused the connection with the following error:
ORA-12514, TNS:listener does not currently know of service requested in connect descriptor 
DEBUG  xxxx-xx-xx xx:xx:xx - ERROR MESSAGE: Listener refused the connection with the following error:
ORA-12514, TNS:listener does not currently know of service requested in connect descriptor 
DEBUG  xxxx-xx-xx xx:xx:xx - Connnection to the database failed or OCU failed to execute the query. </p> 
DEBUG  xxxx-xx-xx xx:xx:xx - Exiting with return code -1
  • Users\<用户名>\AppData\Local\Temp\PTCSOLNINSTALLER_PtcInstall.log 包含以下错误
java.sql.SQLRecoverableException: Listener refused the connection with the following error:
ORA-12514, TNS:listener does not currently know of service requested in connect descriptor 
这是文章 399203 的 PDF 版本,可能已过期。最新版本 CS399203