技术文章 - CS215037
在 SolidWorks 与 Windchill Workgroup Manager 10.2 M030 WWGM-CPS 集成后,在进行各项操作时可能导致 Solidworks 异常退出
已修改: 22-Mar-2016
适用于
- Windchill PDMLink 10.2 M030 CPS04, CPS05, CPS06
- Windchill Workgroup Manager
- SolidWorks 2011, 2012, 2013
说明
- SolidWorks 在进行下述集成操作时可能导致异常退出:
- 当在装配体中进行 插入对象 ,进行零件添加操作时
- 在进行实体建模操作,例如 拉伸 操作时
- 在尝试 导入 CAD 模型至 工作区 时
- SolidWorks 进程奔溃时将会以如下 SolidWorksPerformance.log 信息报告在 SolidWorks 错误报告 中:
SolidWorks Error Report
An error has occurred and SolidWorks needs to restart. SolidWorks will attempt to recover your work on restart if there is recovery data available.
An error has occurred and SolidWorks needs to restart. SolidWorks will attempt to recover your work on restart if there is recovery data available.

SolidWorksPerformance.log:
...
<SWEXH>
<MINIDUMP> "5e09f680-fec6-45db-b946-d9b614f04b7d" </MINIDUMP>
<AD5> auAm_c::iFireEventV;auPartDoc_c::AddItemNotify;auAm_c::XDispatch::GetFirstDocument; auAm_c::GetFirstDocument;auAm_c::getAllOpenModelDocs;auModelDoc_c::XDispatch2::GetTitle; auModelDoc_c::XDispatch2::GetPathName;auModelDoc_c::XDispatch2::GetTitle;auModelDoc_c::XDispatch2::get_Extension;
<EXCEPTION> "Exception e0434352";
<RAWSTACK>
...
<SWEXH>
<MINIDUMP> "5e09f680-fec6-45db-b946-d9b614f04b7d" </MINIDUMP>
<AD5> auAm_c::iFireEventV;auPartDoc_c::AddItemNotify;auAm_c::XDispatch::GetFirstDocument; auAm_c::GetFirstDocument;auAm_c::getAllOpenModelDocs;auModelDoc_c::XDispatch2::GetTitle; auModelDoc_c::XDispatch2::GetPathName;auModelDoc_c::XDispatch2::GetTitle;auModelDoc_c::XDispatch2::get_Extension;
<EXCEPTION> "Exception e0434352";
<RAWSTACK>
...