Windchill PDMLink 中,Windchill Upgrade Manager 无法启动 Method Server,并报错 "Failure to start manager StandardIndexPolicyManager"

已修改: 18-Dec-2017   


适用于

  • Windchill PDMLink 9.1 to 11.1

说明

  • Windchill Upgrade Manager 无法启动 Method Server
  • 报错信息:
Error: Failure to start manager StandardIndexPolicyManager
(wt.services.servicesResource/21) wt.services.ManagerException: Unable to start manager: "wt.index.IndexPolicyManager" with implementation class: "wt.index.StandardIndexPolicyManager"
Nested exception is: wt.services.ManagerException: Couldn't initialize Index manager.
Nested exception is: (wt.access.accessResource/19) wt.access.NotAuthorizedException: ATTENTION:  Secured Action. You do not have the necessary authorization for this operation. Contact your administrator if you believe you have received this message in error.
    at wt.queue.QueueMonitorHelper.queueCheckAccess(QueueMonitorHelper.java:466)
    at wt.queue.QueueMonitorHelper.getWtQueue(QueueMonitorHelper.java:376)
    at wt.queue.QueueMonitorHelper.getWtQueue(QueueMonitorHelper.java:355)
    at wt.queue.QueueMonitorHelper.getWtQueue(QueueMonitorHelper.java:340)
    at wt.queue.StandardQueueService.getQueue(StandardQueueService.java:216)
这是文章 187739 的 PDF 版本,可能已过期。最新版本 CS187739