Article - CS360477

Platform Analytics flink process does not start

Modified: 10-Jan-2022   


Applies To

  • ThingWorx Analytics 8.5

Description

  • Starting Platform Analytics results in service Apache Flink not running
  • Following is seen in Flink log files
  • Starting JobManager (Version: 1.4.0, Rev:3a9d9f2, Date:06.12.2017 @ 11:08:40 UTC)
    OS current user: twxanalytics
    Current Hadoop/Kerberos user: <no hadoop dependency found>
    JVM: Java HotSpot(TM) 64-Bit Server VM - Oracle Corporation - 1.8/25.221-b11
    Maximum heap size: 981 MiBytes
    JAVA_HOME: (not set)
    No Hadoop Dependency available
    ...
    Registered UNIX signal handlers for [TERM, HUP, INT]
    RECEIVED SIGNAL 15: SIGTERM. Shutting down as requested

     