Article - CS243885

ProEngineerStart() API returns PRO_TK_GENERAL_ERROR (-1) if Windchill server has been pre-registered on Creo Parametric Server Manager and Creo Parametric is running in no_graphics mode

Modified: 18-Sep-2021   


Applies To

  • Creo Parametric 2.0 to 8.0
  • Creo Parametric TOOLKIT

Description

  • ProEngineerStart() API returns PRO_TK_GENERAL_ERROR (-1) if Windchill server has been pre-registered on Creo Parametric Server Manager and Creo Parametric is running in no_graphics mode.
  • The following contents are recorded in trail file.
! Message Dialog: Error
! : The server XXXX is currently not available. Check your connection to the server or contact an administrator.
  • APIs related to Windchill server will fail when Creo Parametric is running in no_graphics mode, such as APIs to change workspace, activate server, check if server is online, etc.
This is a printer-friendly version of Article 243885 and may be out of date. For the latest version click CS243885